DefaultSetFlat (user param)

This page applies to Harlequin v13.1r0 and later; both Harlequin Core and Harlequin MultiRIP

Param

Val

ExType

Vers

Use?

HPS

Ref

U

r

H

11.0r5

Y

All

Minimum valid value 0.01 , maximum valid value 100 , default: 0.2 .

The flatness value to set if a job asks for 0 flatness. However the flatness value set will additionally be limited by the /SetFlatRange and /AdobeSetFlat parameters.

The PDF reference states that “a value of 0 specifies the output device’s default flatness tolerance”, so this provides a way of specifying that default, instead of just clipping to the minimum in the /SetFlatRange .